      PRODUCT DESCRIPTION

      Dust sensors are mainly used in solar power plants in photovoltaic arrays, installed on the frame of photovoltaic panels. By continuously measuring the transmission loss caused by pollutants on the glass, the reduction of sunlight reaching the solar modules is calculated.

      PRODUCT FEATURES

      1. Accurately determine when and where to perform cleaning to reduce manual inspection costs for maintenance personnel. By measuring cleanliness levels, it enables operators to identify when dust reaches critical thresholds, thereby optimizing cleaning cycles. This meets the requirements of multiple pollution monitoring points specified in the new IEC 61724-1 standard.

      2. Small panel, using solar industrial standard materials. Suitable for various outdoor environments for long-term use.

      3. High compatibility enables seamless data sharing. It can operate as a standalone dust monitoring system or be seamlessly integrated into any SCADA (Supervisory Control And Data Acquisition) system.

      4. No maintenance required. Simply clean the photovoltaic modules using the same method. Unlike the two radiation meters we produce that need regular cleaning to accurately detect pollution levels, our dust monitoring system only requires cleaning during module maintenance. This convenient approach saves users time and reduces maintenance costs.

      5. Compact and strong, no rotating parts, waterproof.

      6. Continuous multi-frequency modulation light can effectively ensure high-precision dust data detection, and effectively prevent the interference of solar light or other interference light sources on the collected data.

      7. The dust monitoring system operates continuously 24/7, unaffected by day or night. Unlike conventional systems using passive radiation meters, our active light-emitting detection method ensures reliable performance even in complete darkness, delivering accurate readings at night when sunlight is unavailable.

      8. Easy to install and suitable for different panel thicknesses.

      9. With an installation angle output feature, this component maintains the same installation angle as the solar panel. It accurately reflects the solar panel's installation angle and provides real-time feedback to maintenance personnel, enabling them to verify the appropriateness of the installation angle. Additionally, it monitors dust accumulation in the dust monitoring system in real time. If dust is detected, the system promptly alerts maintenance personnel to perform necessary maintenance.

      10. GPS positioning function, which can provide operation and maintenance personnel with the locations information of the power station. (Optional function)

      11. The system can output time (this feature is only available with external GPS), which can be used as a dust monitoring all-in-one machine. With timestamp, it is convenient for customers to track pollution trends based on time.

      12. The system supports external connection of a rear temperature sensor, enabling direct data collection via the dust monitoring system and transmission to the host computer through RS485 communication. This configuration reduces the need for additional rear temperature cables, allowing localized data collection for on-site construction convenience. (Optional feature)

      13. It has the function of temperature compensation, which can ensure the accuracy of the measured value under different ambient temperature.

      SPECIFICATIONS

      Parameter Name

      Parametric description

      Remark

      Pollution ratio

      Dual sensor values50~100%



      Pollution ratio measurement accuracy

      Measuring range90~100%

      Measurement accuracy: ±1% ± 1% of reading FS

      Measuring range80~90%

      Certainty of measurement±2%

      Measuring range80~90%

      The measurement accuracy is ±5%, processed by internal precision algorithm.

      Stability

      Better than 1% of full range (annual)


      Backplane temperature sensor

      Measuring range:-50~150℃

      Definition:±0.2℃

      Resolution ratio:0.1℃

      Apolegamy

      GPS fixed position

      Working voltage:3.3V-5V

      Working current:40-80mA

      Positioning accuracy: average10m,Maximum value 200m.

      Apolegamy

      Output method

      RS485 Modbus


      Linked output (passive normally open contact)

      Generally used to connect cleaning equipment and relays

      Alarm threshold

      You can set upper and lower threshold values


      Working voltage

      DC12V (operating voltage range: DC 9~30V)


      Current range

      70~200mA @DC12V


      Maximum power dissipation

      <2.5W @DC12V

      Low-power design

      Working temperature

      -40℃~+60℃


      Working humidity

      0~90%RH


      Weight

      3.5Kg

      Net weight

      Size

      900mm*170mm*42mm

      Net size

      Sensor line length

      20m